Water Vapor Transmission ASTM E96-00 Proc. B | 820 g / sqm / 24 h |
---|---|
Permeance - ASTM E96-00 Proc. B | 6850 ng / Pa / s / sqm |
Perms - ASTM E96-00 Proc. B | 120 grains /h /sqft /in Hg |
Breaking Load - ASTM D5035-95 (2003) | MD: 75 lb / 2in. (337 N / 50mm) CD: 47 lb / 2in. (210 N / 50mm) |
Elongation at Break - ASTM D5035-95 (2003) | MD: 25% CD: 65% |
Tear Resistance - ASTM D1922-03a | MD: 1078 g CD: 1588 g |
Tearing Strength - ASTM D4533-2004 | MD: 21 lb (96 N) CD: 14 lb (65 N) |
Water Resistance: Impact Penetration AATCC 42-2000 | no water passing |
Water Resistance: Hydrostatic CAN/CGSB-4.2 No 26.3-95/ISO | 642 cm |
Fastener Pull-Through Force - ASTM D3462-03 | 133 N |
Flame Spread - ASTM E84-09 | 25 NFPA Class A; UBC Class I |
Smoke developed - ASTM E84-09 | 105 NFPA Class A; UBC Class I |
Roll weight | approx. 24 lb (11 kg) |
Roll width | 4.92 ft (1.5 m) |
Roll length | 164 ft (50 m) |
Temperature range | -40 °F to +176 °F (-40 °C to +80 °C) |